Required Practical 1 – Specific Heat Capacity
Combined & TripleKey apparatus & reagents: Insulated metal block (e.g. copper, aluminium or iron) with two holes, 30 W 12 V immersion heater and power supply, ammeter, voltmeter, five 4 mm leads, thermometer, pipette with water, balance and stopwatch.
Method overview
- Measure the mass of the metal block in kg, wrap it in insulation, place the heater in the larger hole, add a few drops of water to the smaller hole (improves thermal contact) and insert the thermometer.
- Connect the power pack, ammeter and heater in series, with the voltmeter connected in parallel across the power supply / heater.
- Switch on at 12 V, record the current (I) and potential difference (V), and record the block's temperature every 60 seconds for 10 minutes.
- Calculate heater power (P = V × I) and work done (E = P × t in J), plot temperature against work done, find the straight-line gradient, and calculate specific heat capacity = 1 ÷ (gradient × mass).
- What you measure:
- Mass of block (kg), current (A), potential difference (V), time (s) and temperature (°C) every minute for 10 minutes.
- Equations:
- Power = V × I; Work done = P × t; Specific heat capacity c = ΔE ÷ (m × Δθ) = 1 ÷ (gradient × mass).
Exam tip: The measured specific heat capacity is usually higher than the true value because some thermal energy escapes to the surroundings — insulating the block and putting water or oil in the thermometer hole reduces this error.